DC/AC Pure Sine Wave Inverter SK Series (SK200)
Pure Sine Wave Output (THD < 3%)
Output Frequency: 50/60Hz Switch Selectabe
Input and Output Fully Isolated Design
High Efficiency 87-94% Twin-Color Indicators Display Failure Status
Load and Temperature Controlled Fan
Advanced Microprocessor
SC / OV / UV / OT / OL Protections
Specification Model Number
Item SK200-112 SK200-124 SK200-148 SK200-212 SK200-224 SK200-248
Continuous
Output Power
200W
Maximum
Output Power
(3 min.)
230W
Surge Rating 400W
Input Voltage 12VDC 24VDC 48VDC 12VDC 24VDC 48VDC
Output Voltage 100/110/120VAC +/- 3% 220/230/240VAC +/- 3%
Frequency (Switch Selectable) 50/60Hz +/- 0.05%
Output Waveform Pure Sine Wave (THS < 3%)
Efficiency
(Full Load)
87% 90% 92% 90% 93% 94%
Input
Voltage Regulation
10.5 to 15VDC 21 to 30VDC 42 to 60VDC 10.5 to 15VDC 21 to 30VDC 42 to 60VDC
Failure Indicator Red LED
Protection Overload (Alarm then Shut Down)
Short Circuit (Shut Down)
Reverse Polarity (Fuse)
Over/Under Voltage (Alarm and Shut Down, then Auto Recover)
Over Temperature (Alarm and Shut Down, then Auto Recover)
Safety Meets UL458 Meets EN60950-1
EMC Meets FCC Class A Meets EN55022:1997
Meets EN61000-3-2:1998
Meets EN61000-3-3:1995
Meets EN55024:2001
Meets e-Mark e13
Operating
Temperature Range
0C to 40C
Storage
Temperature Range
-30C to 70C
Cooling Fan controlled by load and temperature
Dimensions 185(L) x 147(W) x 60(H)mm / 7.3(L) x 5.8(W) x 2.36(H) inches
Weight 1.2kg